Beds and patient lifters
Inspection and servicing for electric beds, hoists and patient handling equipment.
1300 651 958Get a QuoteGet a Quote
AGED CARE
Keep beds, patient lifters, mobility aids and medical devices ready for resident care. Coordinate planned testing, maintenance and service records with one experienced team.
Support for aged care facilities
See NES Group Medical in action, then talk to us about a practical testing and maintenance plan for your beds, lifters and clinical equipment.
Get an Aged Care QuoteAged Care Equipment Testing & Maintenance
Keep aged care equipment in reliable working condition with planned checks, service records and maintenance suited to your facility.
Inspection and servicing for electric beds, hoists and patient handling equipment.
Support for wheelchairs, mobility aids and medical devices used in resident care.
Medical device checks and appliance testing under the applicable AS/NZS 3551 and AS/NZS 3760 scope.
Planned and reactive maintenance, digital asset records and service reports.
Equipment and service planning
Plan maintenance with a clear distinction between NES service recommendations and the requirements that apply to each asset.
Recommendations are not universal compliance deadlines. The fixed intervals below are NES planning recommendations, unless a manufacturer's instructions specify the same interval for that model. Confirm the final schedule against the instructions for use, applicable standards and local requirements, equipment condition, usage and facility risk assessment. Routine pre-use checks, fault reporting and required operational checks continue between service visits.
| Equipment type | Planned service interval | Basis of interval | Applicable requirements and scope |
|---|---|---|---|
| Electric hospital beds | 12 months | NES recommendation | Follow the bed manufacturer's maintenance schedule. Apply AS/NZS 3551 where the bed is medical electrical equipment; include mechanical operation, brakes, controls and moving components. The 12-month interval is not presented as a universal AS/NZS 3551 requirement. |
| Patient lifters / hoists | 6 months | NES recommendation; confirm the model's instructions | Follow manufacturer-specified inspection, maintenance and any load-test requirements. ISO 10535 is a relevant hoist product standard; this guide does not attribute a universal six-month service or load-test requirement to it. Confirm sling inspection and replacement separately. |
| Wheelchairs / mobility aids | 12 months | NES recommendation | Manufacturer instructions and facility risk assessment determine checks for the frame, brakes, castors and other components. Powered devices may need additional electrical and battery checks. |
| Air mattresses / alternating pressure devices | 12 months | NES recommendation | Follow manufacturer maintenance and performance checks. Apply AS/NZS 3551 where the device is medical electrical equipment; assess pump, pressure performance, controls and condition as applicable. |
| Vital signs monitors | 12 months | NES recommendation | AS/NZS 3551 provides the medical equipment management framework. The manufacturer's instructions and measurement functions determine the performance checks and calibration schedule for each device. |
| Defibrillators (AEDs) | Manufacturer's schedule; include in the facility's planned review program | Manufacturer requirements | Follow the specific model's readiness checks, self-test alerts and battery/pad expiry and replacement instructions. Apply AS/NZS 3551 as applicable. A technician visit does not replace routine readiness checks. |
| Electrical appliances (non-medical) | Determine for the environment, use and jurisdiction | Applicable standard and local requirements | Use AS/NZS 3760 for equipment within its scope and any applicable local electrical safety requirements. Intervals vary; a blanket 6–12-month period is not appropriate. Confirm RCD testing separately. |
| Examination / treatment tables | 12 months | NES recommendation | Follow manufacturer instructions for the frame, movement, controls and mechanical components. AS/NZS 3551 applies where the powered table is medical electrical equipment. |
| Medication refrigerators | 12 months for planned technical service, plus required temperature monitoring | NES service recommendation; storage checks follow applicable guidance | Follow manufacturer instructions and the facility's medicine-storage procedures. For vaccine storage, follow the National Vaccine Storage Guidelines — Strive for 5. Technical servicing does not replace routine temperature monitoring. |
| Shower trolleys / hygiene chairs | 6–12 months | NES recommendation, adjusted for use and condition | Follow manufacturer instructions and risk assessment for brakes, frames, adjustment mechanisms and corrosion checks. Assess any powered components under the applicable equipment requirements. |
How to use the standards: AS/NZS 3551 concerns medical equipment management; AS/NZS 3760 concerns in-service safety inspection and testing of electrical equipment within its scope. Naming a standard does not establish that every item needs the same service interval or that the facility complies with all of its provisions. Confirm the current applicable edition, scope and asset-specific schedule when planning the work.
Sources: The Aged Care Quality and Safety Commission emphasises manufacturer recommendations, maintenance responsibilities and records. See AS/NZS 3760, ISO 10535 and the National Vaccine Storage Guidelines — Strive for 5. Statutory electrical requirements can differ between jurisdictions.
Get an Aged Care QuoteWhat the visit covers
Aged care equipment maintenance combines mechanical inspection, functional testing and electrical safety checks where applicable. The work should reflect what the item does, how it is used and the manufacturer's servicing instructions.
NES can help coordinate medical equipment testing and calibration alongside bed, lifter and mobility-equipment maintenance, with the scope confirmed before the visit.
Plan access to beds, lifters, wheelchairs and hygiene equipment. Identify reported faults, worn components or operating issues so they can be assessed during the agreed service.
Review the safety and performance of medical devices such as vital signs monitors and AEDs. Confirm the required tests and any calibration needs for the make, model and clinical use.
Medical equipment and non-medical appliances can require different checks. NES will confirm the applicable AS/NZS 3551 or AS/NZS 3760 scope rather than treating every asset as a general test-and-tag item.
Record issues found and agree the next action. Repairs, replacement parts and further investigation can be discussed where required, with findings available to your maintenance team.
Records and ongoing oversight
Good service records help your team see what has been checked, what needs attention and when the next review is due. They also support maintenance planning and preparation for internal reviews and accreditation assessments.
The Aged Care Quality and Safety Commission's equipment guidance highlights clear maintenance responsibilities, manufacturer recommendations and follow-up actions.
Start with asset identifiers, equipment types, locations and any available make, model and serial-number details. Share previous reports so the service history can inform the plan.
Keep the service date, checks completed, results, reported faults and recommended next steps together. Allocate responsibility for repairs and outstanding actions.
Group equipment by location or service due date, agree access arrangements and identify items that cannot be taken out of use at the same time. For multiple facilities, discuss a coordinated schedule and consistent reporting.
Plan your next service
Tell us your facility location, equipment types, approximate quantities and any upcoming service dates. An existing asset list is helpful if available.
We discuss the work required, quote and access arrangements with your team, including resident routines and equipment availability.
Receive records of the agreed work, findings and recommended next steps so your team can plan maintenance and track outstanding actions.
Frequently asked questions
Use the equipment interval guide above as a starting point, then confirm each asset's schedule against manufacturer instructions, condition, usage and the facility risk assessment. NES can help organise a practical maintenance calendar from your equipment list and previous reports.
No. An electrical check does not replace the mechanical and functional inspections required for a bed, hoist or other resident-handling device. Confirm the complete service scope, including any manufacturer-specified safety or load tests.
Retain the asset details, date, work completed, results, faults identified and follow-up recommendations. Use these with your equipment register to track due dates and allocate responsibility for outstanding actions.
Share your asset list, including beds, lifters, wheelchairs and clinical devices, so NES can confirm the service scope.
NES can tailor a maintenance plan around equipment use, manufacturer recommendations and facility requirements.
Your facility location, equipment types, approximate quantities, known issues and preferred timing help us scope the work. Share any asset list or previous service records you already have.
Yes. Share your site locations and requirements so we can discuss a coordinated program, confirm coverage and agree reporting and scheduling for each facility.
Talk to NES
Share your facility location, equipment types and preferred timing. We’ll help confirm the service scope and next steps.
Service enquiry
Tell us what your facility needs and our team will help scope the right service.