AS/NZS 3760 Test & Tag
AS/NZS 3760 Test & Tag for Clinics & Healthcare Facilities
Every clinic runs on more than its medical devices. Computers, fridges, power boards, ster/wash bays, the kettle in the staff room — all of it is electrical equipment, and all of it falls under AS/NZS 3760. We test and tag the lot, onsite, in the same visit as your medical equipment testing.
We are proud to be Australia’s highest-reviewed medical equipment testing provider — more 5-star Google reviews than any company in our field.
What is AS/NZS 3760?
AS/NZS 3760 is the Australian and New Zealand standard for in-service safety inspection and testing of electrical equipment — what most people just call “test and tag”. It sets out how a competent person inspects, tests and labels electrical equipment that’s already in use, so a frayed cord or a failing power board gets caught before it hurts someone.
The current edition is AS/NZS 3760:2022, published on 8 June 2022. It replaced the 2010 version after a full revision, and the title now includes RCDs — the safety switches that cut power when something goes wrong. If your last test-and-tag round was quoted against the 2010 standard, you’re working from a document that’s been retired.
It applies almost everywhere electrical equipment is used — offices, factories, and yes, healthcare facilities. But for a clinic, there’s a catch worth understanding before you book anything.
AS/NZS 3760 or AS/NZS 3551 — which one covers what?
Here’s the part clinics get wrong, and it matters.
AS/NZS 3760 excludes medical equipment. Your ECG, your defibrillator, your patient monitors — they’re not tested under 3760. They fall under AS/NZS 3551, the standard built specifically for medical electrical equipment, because a device a patient is physically connected to needs a stricter check than a desktop PC.
So 3760 covers everything else plugged in around your practice:
- Computers, monitors, printers
- Fridges and medication refrigerators (the appliance’s electrical safety — not the temperature monitoring)
- Power boards and extension leads
- Kettles, microwaves, staff-room appliances
- Vacuum cleaners and cleaning equipment
- Chargers, lamps, fans, heaters
The takeaway: a compliant clinic needs both. AS/NZS 3551 for the medical devices, AS/NZS 3760 for the general electrical equipment. Book one without the other and you’ve still got a gap your assessor can find. We do both in a single onsite visit, so there’s nothing to coordinate and nothing left uncovered.
How often does equipment need testing?
AS/NZS 3760 doesn’t set one blanket interval. It bases the frequency on the environment and how hard the equipment’s life is — the rougher the use, the more often it’s checked. The standard’s tables run from every few months for the highest-risk gear out to several years for low-risk equipment that sits on a desk and never moves.
A rough sense of how that scales:
| Environment / use | Typical interval |
|---|---|
| Hired or leased equipment | Every 3 months |
| Factories, workshops, commercial cleaning gear | Every 6 months |
| Equipment that’s flexed, moved or knocked about | More frequent |
| Low-risk equipment in a clean, stable setting (e.g. an office PC) | Up to 5 years |
Healthcare environments generally sit toward the more frequent end, because equipment moves between rooms, gets cleaned constantly, and runs all day. We set the right interval for each piece against the standard and then track it for you, so nothing quietly lapses.
What changed in AS/NZS 3760:2022
The 2022 revision wasn’t cosmetic. A few changes matter for any practice booking the service:
Record-keeping got real. A third-party tester now has to document the actual measurements from each test — earth continuity resistance, insulation resistance, leakage current — not just stamp it “pass”. You should be receiving real data, not a tick.
Equipment registers. Keeping a register of what’s been tested moved from good habit to expectation. (We keep yours as part of every visit, so this one’s already handled.)
Calibrated testers. The standard tightened the rules on the testing instruments themselves — they have to be verified against a calibrated source, within the manufacturer’s timeframes. A tester using out-of-cal equipment can’t give you a result you can trust.
Competent person. The definition of who’s allowed to test and tag was expanded — they’re expected to keep their skills current and understand the electrical risks they’re assessing, not just follow a checklist.
If whoever’s doing your test and tag is still handing you pass/fail stickers and no measurements, they’re working to a standard that no longer exists.
What a test & tag actually involves:
Heres what a test & tag actually involves
Step 1 — Visual inspection. Every item is checked by eye first — frayed cords, cracked casings, bent plug pins, damaged power boards. A lot of faults are caught here before a meter ever touches the device.
Step 2 — Electrical testing. The device is tested for earth continuity, insulation resistance, polarity and current leakage — the checks that prove it’s safe to touch and safe to run.
Step 3 — Tagging. Anything that passes gets a tag showing the test date, the next due date, and who tested it. Anyone can see at a glance that it’s current.
Step 4 — Documentation. The real measurements are logged against your asset register, and anything that failed is flagged for repair or replacement and pulled from service. You finish the visit knowing exactly where you stand.
Test & tag, done alongside your medical equipment testing
We’re a biomedical service organisation first, which means we’re already at your practice testing the medical equipment under AS/NZS 3551. Adding 3760 test and tag to the same visit is the efficient move — one technician, one booking, one combined record, both standards covered.
You get measurements not stickers, a live asset register, and automated reminders before anything’s due again. We’ve done this for over 3,500 healthcare sites across NSW, ACT, VIC, QLD, NT and SA for more than twenty years, metro to remote, with no surprise travel fees.
Why Choose NES Group Medical?
Australia-wide service coverage
Experienced, qualified biomedical technicians
Simple onboarding & checklists
Online asset database & automated recall reminders
Custom maintenance plans
Support for accreditation and compliance audits
Let us take care of the compliance— accreditation Ready documentation .
NES Group Medical provides the most detailed and accurate compliance documents in the industry ready to hand over stress free on accreditation day:
- AS/NZS 3551 safety test certificates
- Calibration results
- Performance test logs
- Visual inspection reports
- Asset registers
- Service & repair notes
- Online portals with complete asset history
- Detailed checklists ensure nothing is missed
This documentation is formatted for:
- AGPAL
- RACGP
- QIP
- HSO
- Aged Care Quality Standards
📞 Call 1300 651 958 or enquire online to book your next service..
FAQ: Medical Equipment Calibration, Service & Repairs
Absolutely. You will definitely need to have your autoclave validated even if it has been serviced regularly. Servicing your autoclave is also a very important task but is not the same as autoclave validation.
Autoclave validation is a documented process of installation, operational and performance qualification (IQ/OQ/PQ) carried out to the manufacturer’s requirements and AS/NZS 5369:2023. It confirms that heat, time, pressure and steam penetration are performing correctly and reaching the required values throughout the chamber and load.
Autoclave servicing is completed in line with the manufacturers requirements to ensure things like filters, seals, sensors, pumps, and chamber are correctly maintained to avoid breakdowns and faults from occurring. Similar to taking your car to the mechanic for a service. Service intervals will depend upon the type of autoclave and frequency of use, some practices may require a service annually others quarterly.
1. Our technicians use high pressure and high temperature data loggers to map the internal chamber pressure, heat and penetration over time at various locations inside your autoclave. It is important to also identify your chamber “cold spot”.
2. Steam penetration is assessed using a process challenge device (PCD) with a challenge pack and full challenge load. Chemical and bio-enzymatic indicators placed inside the PCD are read immediately after the cycle to confirm adequate steam penetration and air removal; these indicators are not incubated.
2a. Where biological indicators are required, we place sealed vials containing Geobacillus stearothermophilus spores in specific locations in the chamber, run the test cycles, then incubate the vials to confirm the spores have been inactivated.
3. We plug the autoclave into our electrical safety analyser which runs through a series of electrical tests to ensure the autoclave is safe to operate.
4. Visual examination of door locking hardware, seals, chamber, pumps and general condition of the autoclave.
5. Issue you with your autoclave validation certificate and report.
All our processes are completed in line with manufacturers recommendations and Australian Standards and can take up to 4 hours to correctly complete.
NES Group’s service engineers are trained in the current Australian Standards AS/NZS 5369:2023 and AS/NZS 3551:2012, so you can be assured that your autoclave is correctly validated and performing to Australian Standards and the manufacturers specifications.
Yes. NES Group can also test and tag regular electrical equipment in accordance with AS 3760 in the same visit to minimise disruption to your practice and managing of multiple testing companies and testing registers at surprisingly affordable rates even though our technicians are specialised, we offer this service at the same rate as most electricians and test and tag companies to make life easier for our customers.
No! Our aim is to make meeting your annual calibration requirements easy and affordable. We have invested heavily in the training of our staff and in the latest and most efficient test equipment to dramatically reduce the labour time required to complete your testing, by doing this we are able to reduce the costs associated to properly maintaining your equipment making it very affordable to stay compliant for even the smallest of practices.
Our customers get the options of:
No Lock In Contract Annual Service
Testing under this arrangement is done on a year by year basis with not lock in contract, we contact you the following year when you are due.
3 Year NEScare Service Agreement
Most of our larger healthcare groups take advantage of group procurement service agreements, we can combine all of your practices as a group for a 3 year term benefits of this are:
– Programmed service intervals based on your requirements making maintenance of your equipment easy
– Access to our online portal
– Access to discounted NEScare rates
– Lock in todays discounted prices for the next 3 years
– Group Procurement Discounts
– Free access to loan equipment
– Same day priority service for most areas
In Summary:
- We make it very affordable to have your autoclave correctly validated and to stay compliant even for the smallest of businesses.
- Pricing for our Autoclave Validations is very affordable, you cannot afford not to do it.
- We rely on our great service, expert knowledge and outstanding value to keep our customers retuning on their own terms.
- We do offer flexible 3 to 5 year NESCare service and maintenance packages so that our customers have the option to further reduce service and maintenance costs.
– All Types Of Medical Equipment and Surgical Devices AS/NZS 3551:2012
– Autoclave Validation AS/NZS 5369:2023
– Patient Area Testing Body and Cardiac AS 3003
– General Electrical Appliances AS/NZS 3760:2022
– ECG Machines
– Vital Signs Monitors
– Blood Pressure Monitors
– Blood and Vaccine Fridges
– Scales and Body Composition Analysers
– Spirometers
– Pulse Oximeters
– Digital Thermometers
– Portable Suction Units
– Doppler Ultrasounds
– Nebulisers – Defibrillators
– Electrosurgical Units / Hyfrecators
– Examination Lights
– Light sources
– Operating Theatre Lights
– Medical Gas Pendants
– Medical Gas Systems
– Operating Tables and Beds
– And most other types of medical equipment